Mfg Part Number: MIL-PRF-39019 3 | Alternate P/N: MILPRF390193 | NSN : 5925-01-485-9638 | NIIN : 014859638 | CAGE Code : 1Z496 | Manufacturer: Ap Labs Inc | Item Name : Circuit Breaker | FSC : 5925 Circuit Breakers |
Circuit Breaker014859638 Thank you for your interest in the various NSN parts and components that we offer on Hardware Domain. NSN 5925-01-485-9638 is listed alongside the part number MIL-PRF-39019 3, having been manufactured by Ap Labs Inc. If you would like to procure NSN part MIL-PRF-39019 3, or other items related to Circuit Breaker, we invite you to first begin with a quote for your comparisons which you may receive by completing the RFQ form that is provided below. When completing our form, we ask that you offer us as many details as you can regarding your needs so that we may craft a solution that is individually personalized.
This Ap Labs Inc part MIL-PRF-39019 3 was produced under the CAGE Code 1Z496, which ensures that you are procuring exactly what you require. To guarantee the quality of our offerings, we enact a strict NO CHINA SOURCING pledge and subject countless items to rigorous quality assurance measures as necessary. As a culmination of our efforts in terms of quality control and export compliance, we are proud to operate with AS9120B, ISO 9001:2015, and FAA AC 00-56B certification and accreditation. Complete an RFQ form today for NSN 5925-01-485-9638 or get in contact with one of our representatives to see how Hardware Domain can fulfill all your part requirements with ease.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-485-9638 Item Description: Circuit Breaker | 5925 | 014859638 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Mil-Prf-39019 3 | 5 | 1 | 4 |
MRC | Criteria | Characteristic |
---|---|---|
AKPX | Pole Quantity | 2 |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
CPLM | Maximum Continuous Load Current Rating Per Pole | 10.0 AMPERES AC ALL LOCATIONS AND 10.0 AMPERES DC ALL LOCATIONS |
ABXD | Bushing Length | 0.332 INCHES MINIMUM AND 0.380 INCHES MAXIMUM |
FREQ | Frequency In Hertz | 400.0 ALL LOCATIONS |
AJWX | Mounting Surface To Terminal End Distance | 1.828 INCHES MAXIMUM |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 300.0 AC ALL LOCATIONS AND 500.0 DC ALL LOCATIONS |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 240.0 AC ALL LOCATIONS AND 50.0 DC ALL LOCATIONS |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRQ | Reset Method | MANUAL |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
ADAT | Body Width | 1.281 INCHES MAXIMUM |
CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
ADTV | Case Material | METAL |
CPRW | Actuator Function | TRIP-RESET |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
CPRX | Actuator Position Designation | BETWEEN POLE ONE AND TWO |
AXHR | Mounting Facility Type And Quantity | 1 THREADED BUSHING W/PANEL SEAL |
THSD | Thread Series Designator | UNEF |
CQJX | Nominal Thread Size | 0.375 INCHES |
AAQL | Body Style | |
ADAQ | Body Length | 1.562 INCHES MAXIMUM |
BBRJ | Special Handling Feature | MAGNETIC |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 0.906 INCHES MAXIMUM |
APNQ | Arc Quenching Method | MAGNETIC BLOWOUT |
CMLP | Thread Quantity Per Inch | 32 |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.594 INCHES MINIMUM AND 0.656 INCHES MAXIMUM |
CPRH | Circuit Protection Type | REVERSE PHASE ALL LOCATIONS |
ZZZK | Specification/Standard Data | 81349-MIL-PRF-39019/3 GOVERNMENT SPECIFICATION |
AFJN | Fragility Factor | MODERATELY RUGGED |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 0.055 MINIMUM AT 200 PCT ALL LOCATIONS AND 0.950 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
TTQY | Terminal Type And Quantity | 4 SCREW |
CQXF | Inclosure Protection Type For Which Designed | DUSTPROOF AND FUNGUS PROOF AND HERMETICALLY SEALED AND MOISTURE PROOF |
MRC | Decoded Requirement | Clear Text Reply |
TEST | Test Data Document | 81349-MIL-PRF-39019 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote